Customer Branded Products
Structural Epoxy - Technical Data Sheet
Advantages
| Application
Equipment | Description
| Instructions for Use
Other Accessories
| Packaging | Precautions
| Properties
Quantity
Estimating Guide |
Statement of
Responsibility | Storage
Customer
Branded Products (Main Page)
Structural Epoxy Hardener Safety Data Sheet
Structural Epoxy Resin Safety Data Sheet
Structural Epoxy Adhesive Paste TP
Structural epoxy adhesive paste and filler
For speedy and permanent patching repairs to concrete structures,
bonding of precast concrete components and all repair work to concrete
cementitious substrates where strength, impermeability to water, and
resistance to aggressive chemicals is essential; emergency repairs to
concrete structures, sea walls, and industrial floors in chemical
handling and process areas.
The thixotropic nature of Structural Epoxy Adhesive Paste TP makes
the product ideal for setting starter bars, dowels, holding down bolts
and anchoring in general.
-
Early development of initial hardness, minimises
maintenance disruption.
-
Pre-weighed quality controlled materials ensure
consistency and reduce risk of site errors
-
Two pack colour coding gives visual check on correct
mixing.
-
Unaffected by a wide range of acids, alkalis and
industrial chemicals.
-
3 to 4 times stronger than typical concrete.
Excellent resistance to abrasion and impact.
-
Natural grey colour sympathetic to aesthetic
requirements.
Structural Epoxy Adhesive Paste TP is part of Svenic Australia's
range of structural adhesives and grouts for use in the construction
industry. It combines ease of mixing and application with a
two-component, epoxy paste consistency, structural adhesive/filler. It
cures, with minimal shrinkage, at temperatures above 5°C to a very
strong, dense solid.
The mixed material is applied to a suitably prepared surface and quickly
cures to form a complete impermeable repair unaffected by many forms of
chemical attack.
It is supplied as a two pack colour coded material in preweighed
quantities ready for on-site mixing and use.
Data quoted typical for this product but does not constitute a
specification.
1.5 litre mix at 25°C -
25-35 minutes.
Note: To obtain maximum pot life, spread into a thin (less than
10 mm) layer immediately after mixing. |
| 24 hours. |
| 7 days. Below 20°C the
curing time will be increased. |
| 5°C |
| 50°C |
| 1.7 (approx.) |
Chemical resistance:
| Excellent |
| Excellent |
| Excellent |
| Excellent |
| Very Good |
| Very Good |
| Very Good |
| Very Good |
Colour:
Grey, when mixed (may yellow and/or darken when exposed to sunlight
or certain chemicals).
Preparation
All grease, oil, chemical contamination, dust, laitance and loose
concrete must be removed by scabbling or light bush hammering to provide
a sound substrate.
All concrete must be at least 14 days old prior to treatment. Steel
surfaces should be grit blasted to white metal. Surfaces which show any
traces of oil must be degreased with a chemical degreaser prior to grit
blasting.
Mixing
Thoroughly mix resin (white) and hardener (black) until an even grey
colour is obtained. Before a new cartridge kit is introduced into the
hole, dispense the first part (at least 20 ml) of the cartridge into a
cup etc, until the resin and hardener is of a homogenous and consistent,
even grey colour.
Application
Apply the mixed Structural Epoxy Adhesive Paste TP with a notched
trowel, putty knife, caulking gun, etc., depending upon the application.
Bonded surfaces should be held rigidly together until the Structural
Epoxy Adhesive Paste TP has set.
Cleaning
All tools and equipment should be cleaned immediately after use with
solvent such as Xylene. Hardened material can only be removed
mechanically.
CAUTION: Some solvents contain
potentially harmful chemicals like Toluene. They should only be used in
well ventilated areas. Avoid direct skin contact. For further
information, refer to the specific instruction sheet on the solvent
used.
| 450RPSEATP |
450 ml Twin Cartridge Kit (150:300
ml)
Structural Epoxy Adhesive Paste TP
with one 12.5 mm dia x 18
Element Static Mixer with taper per kit. |
15 |
| 6000SEATP |
6 Litre Kit (2000:4000 ml tin)
Structural Epoxy Adhesive Paste TP |
2 |
|
Note: This kit does not include any
accessories. |
|
Note: Bulk drums available of each resin and hardener.
| 300XPPM1 |
Hand Operated Applicator for Twin Cartridges
Set 150:300 ml |
6 |
| 300APPA1 |
Air Operated Applicator for Twin Cartridges
Set 150:3000 ml |
1 |
Additional Static Mixers
available.
The Table below indicates the volume of Structural Epoxy Adhesive
Paste TP in ml/100 mm bond
| 20 |
25 |
|
|
|
|
|
| 25 |
50 |
40 |
25 |
|
|
|
| 32 |
80 |
70 |
60 |
40 |
|
|
| 38 |
|
100 |
100 |
75 |
|
45 |
| 45 |
|
|
150 |
130 |
100 |
45 |
| 50 |
|
|
|
180 |
150 |
90 |
| 62 |
|
|
|
|
280 |
225 |
These figures allow for a 25% wastage factor.
Structural Epoxy Adhesive Paste TP has a shelf life of 12 months when
stored in a dry place below 35°C in unopened containers.
Keep cartridges and tins closed tightly when not in use.
Do not interchange "D" plugs or lids or in other way
contaminate "A" Components with "B" or vice versa.
Do not store in conditions of excessive heat or cold.
Health and Safety
Prolonged and repeated skin contact with epoxy resins and curing
agents may cause dermatitis in persons sensitive to these products.
Gloves, barrier creams, protective clothing and eye protection should be
worn when handling these products. If poisoning occurs, contact a doctor
or Poisons Information Centre. If swallowed, do NOT induce vomiting -
give a glass of water. If in eyes, hold eyes open, flood with water for
at least 15 minutes
If skin contact occurs, remove contaminated clothing and wash skin
thoroughly. Material Safety Data Sheets are available. Read Material
Safety Data Sheets, Technical Data Sheet and label carefully before
first use of any product
Fire
Structural Epoxy Adhesive Paste TP is non-flammable
Handling Instructions
Refer to the material safety data sheet (MSDS) before handling the
product. Follow instructions for safe handling.
Avoid direct skin contact. Gloves and overalls should be worn. Should
direct contact occur, wash affected areas thoroughly with soap and
water. Do not use solvents to remove product from skin.
Respirators should be worn in confined areas or in the case of
prolonged exposure to vapours. Contaminated clothing should be laundered
as soon as possible.
The information given in this publication is based on the present
state of our knowledge. Buyers and users must make their own assessment
of our product under their own conditions for their own requirements.
No responsibility is accepted save those non-excludable conditions
stated or implied by any Federal or State Legislation or law of a
territory.
CONTACT POINT
Peter Coundouris General Manager Svenic Australia (Contact
Information below)
OTHER CONTACT
Poisons
Information Centre 13 11 26
|